EMC laboratory

The use of technical systems places high demands on functional safety and interference immunity, which should be taken into account as early as the development phase. In our pre-compliance laboratory for electromagnetic compatibility (EMC laboratory), devices are tested for their immunity and emissions and the results are compared with the underlying standards. If the system to be tested does not meet the relevant requirements, we suggest measures for improvement.

 

EMV-Flyer

Offer

Immunity tests and emission measurements for conducted and radiated interference can be carried out in our EMC laboratory. Our EMC laboratory has a shielding cabin, a compact GTEM cell and a power quality measuring station. The GTEM cell is calibrated up to 6 GHz. This makes our laboratory ideal for testing the EMC properties of your device during development. We support you during development and advise you on the optimization of EMC properties. We are happy to help you with your EMC assessment before you visit a costly accredited laboratory.

We test to the following standards

Conducted measurements

• from 9 kHz to 30 MHz EN 55011, EN 55014, EN 55032

• Power Quality EN 61000-3-2

Radiated measurements

• from 30 MHz to 6 GHz EN 55011, EN 55014, EN 55032

• Device size Cube edge length 60 cm

Electric fields

• EN 61000-4-3 • Gerätegrösse Würfel Kantenlänge 60 cm

Electrostatic discharge ESD

• EN 61000-4-2

Surge voltage (surge)

• EN 61000-4-5

Fast transients (burst)

• EN 61000-4-4

Voltage dips and interruptions (power fail)

• EN 61000-4-11

• EN 61000-4-8

High-frequency antenna systems and electromagnetic compatibility